Warmerdam 2022 gait set (cluster set)

The marker set behind the 3D Mocap Analysis example gait trial: 47 body markers from the Warmerdam et al. (2022) open dataset, with rigid four-marker clusters on each thigh and shank and a three-marker cluster on the sternum. This page documents the labels as they appear in the file, what biomex derives from them, and the skeleton it fits.

Other sets: biomex Minimal Marker Set

⇩ PDF guide
Warmerdam 2022 gait set  47 body markers + 8 static-only · rigid clusters on sternum, thighs and shanks · the /mocap example trial
B
biomex.studio
lf_hd m_ster1–3 l_sho l_ua l_elbl l_frm l_wrr l_wru l_hand r_asis l_asis l_th1–4 l_sk1–4 l_ank l_toe rf_hd lf_hd m_ster1 m_ster2 m_ster3 r_sho l_sho r_ua l_ua r_elbl l_elbl r_frm l_frm r_wrr l_wrr r_wru l_wru r_hand l_hand r_asis l_asis r_th1 r_th2 r_th3 r_th4 l_th1 l_th2 l_th3 l_th4 r_sk1 r_sk2 r_sk3 r_sk4 l_sk1 l_sk2 l_sk3 l_sk4 r_ank l_ank r_toe l_toe FRONT lb_hd rb_hd l_psis r_psis l_heel r_heel lb_hd rb_hd l_sho r_sho l_ua r_ua l_elbl r_elbl l_frm r_frm l_wru r_wru l_hand r_hand l_psis r_psis l_th1 l_th2 l_th3 l_th4 r_th1 r_th2 r_th3 r_th4 l_sk1 l_sk2 l_sk3 l_sk4 r_sk1 r_sk2 r_sk3 r_sk4 l_ank r_ank l_heel r_heel BACK
anatomical marker cluster / tracking marker same marker, labelled on the other viewLabels as in the dataset: l_ / r_ = the subject’s own side; th = thigh, sk = shank, hd = head, ster = sternum.
Detailed marker description
B
biomex.studio
#LabelRefΒΉSegmentLocationType
Loading the marker table from lib/markersets.js…
ΒΉ Nearest van Sint Jan (2007) landmark code where the placement matches one; – for cluster, head and shoe markers.Amber = cluster; grey = static calibration only. Placements: Supplementary Table S1, Warmerdam et al. (2021).
Additional information
B
biomex.studio

Source

Warmerdam E, Hansen C, Romijnders R, Hobert MA, Welzel J, Maetzler W (2022). Full-Body Mobility Data to Validate Inertial Measurement Unit Algorithms in Healthy and Neurological Cohorts. Data 7(10):136, doi:10.3390/data7100136. Dataset: doi:10.6084/m9.figshare.20238006. The /mocap example trial is one overground walk (participant pp013, gait1) from this dataset, converted to Qualisys TSV with no gap-filling, so the real dropouts are kept.

Dataset licence is CC BY-NC-SA (the paper is CC BY). Confirm that hosting one converted trial as a teaching example on biomex.studio is within that licence.

Capture, as described in the paper

  • Qualisys optical motion capture at 200 Hz; at least three 19 mm reflective markers per body segment; 47 markers on the body.
  • Markers on the sternum, thighs and shanks were fixed as rigid clusters; the others on the skin or tight-fitting clothing, as far as possible on bony landmarks.
  • Eight static markers (medial humeral epicondyles, medial and lateral femoral epicondyles, medial malleoli; labels l/r_st_*) were worn only during the static calibration in a neutral pose and are not in the walking trials. The 2022 data paper says six; the protocol lists eight.
  • Data were labelled in Qualisys Track Manager and otherwise left raw: no gap filling, no filtering. Placements in the table are from Supplementary Table S1 of the protocol (Warmerdam et al. 2021, Sensors 21:5833).
  • start_1/2 and end_1/2 in the file are walkway markers on the floor, not on the body.

What biomex derives from it

  • Hip joint centres from the ASIS pair and the PSIS midpoint by the Bell, Pedersen & Brand (1990) regression.
  • Wrist centres as the midpoint of the radial and ulnar wrist markers; head centre as the centroid of the four head markers; cluster centroids for sternum, thigh and shank.
  • Knee centre is estimated: the set has no knee marker, so /mocap uses the centroid of the eight thigh and shank cluster markers (the midpoint of the two cluster centroids) for display. Treat knee angles from this set as indicative only.
  • Skeleton: loading…

Limits

Elbow and knee are lateral or estimated, the hands carry one marker, and about 15% of marker samples are missing in the example trial. That is what makes it a good teaching file for the gap-fill and merge tools, and a poor one for publishable joint kinematics without the static calibration.

Using it in /mocap

  • Load example gait trial → the labels are recognised and the skeleton is fitted automatically (Tools → Skeleton model).
  • Switch Lines / Solid / Bones under Skeleton model; the Bones view poses stylised bones from the marker frames.
  • Try Gap-fill (Markers tab) and the merge suggestions on the dropouts before measuring.

Reading the clusters

Each thigh and shank cluster is a rigid plate of four markers on the lateral side; the sternum cluster is a three-marker plate with ster1 at the top. The wrist markers sit on the wrist IMU rather than on the skin, so they stand a little proud of the styloids.

Warmerdam, E. et al. (2022). Data 7(10):136 · Warmerdam, E. et al. (2021). Sensors 21:5833 · Bell, A.L., Pedersen, D.R. & Brand, R.A. (1990). J Biomech 23(6):617–621.biomex.studio · v1.0 · November 2026